More accurate blood pressure measure method


Tuesday, 22 August, 2017

More accurate blood pressure measure method

Automatic blood pressure devices are prone to significant errors, sometimes leading to the prescription of blood pressure-lowering medications to patients who don’t actually need them.

Now, researchers have developed a method to more accurately measure systolic blood pressure.

Based at the Jerusalem College of Technology and the Shaare Zedek Medical Center in Israel, the research team has developed a device — using a technique called photoplethysmography — that uses a pressure cuff wrapped around the arm and an electro-optic probe on the finger.

“The finger probe is similar to that of pulse oximeter: it includes a light-source emitting light into the finger and a detector, which measures the light transmitted through the finger,” Meir Nitzan, PhD, the new study’s first author, explained. “The transmitted light exhibits pulses at the heart rate, due to cardiac-induced blood volume changes in the finger tissue.

“When the cuff pressure increases to above systolic blood pressure these pulses disappear, and when the cuff pressure decreases to below systolic blood pressure they reappear. This effect enables the determination of systolic blood pressure.”

A systolic blood pressure measurement of 140 mmHg or higher and a diastolic measurement of 90 mmHG or higher (140/90 mmHg) is considered high. Blood pressure is usually assessed using either a manual (auscultatory) or automatic (oscillometry) meter in a doctor’s office or hospital. However, these measurements can be affected by ‘white coat syndrome’ — a patient’s fear or anxiety in a doctor’s office causing their blood pressure to measure above normal levels. To avoid the white coat effect, at-home automatic measurements taken by the patient may be required, but available oscillometry-based automatic meters offer a low level of accuracy.

“The automatic oscillometric technique is less accurate than the manual auscultatory technique, when both are used in the clinician’s office,” Nitzan said. Currently available automatic blood pressure measurement devices are commonly off by 10 to 15 mmHg. This is mainly due to indirect determination of the blood pressure from the oscillometric air-pressure wave measurements taken by automatic devices.

A patient with an incorrect high blood pressure diagnosis may be prescribed blood pressure-lowering medication unnecessarily. These medications can cause patients’ blood pressure to dip too low (hypotension); elderly patients are especially at risk. Side effects of hypotension can include short-term symptoms such as dizziness and fainting, and long-term problems such as insufficient blood supply to vital organs, which can lead to acute kidney injury and cognitive impairment.

Nitzan recently presented his findings at an American Physiological Society conference, Cardiovascular Aging: New Frontiers and Old Friends conference, in Colorado, USA.

Image credit: ©stock.adobe.com/au/DragonImages

Related News

New public health campaign to improve pregnancy outcomes

The Preterm Birth Prevention campaign 'See, Stop, Scan' aims to promote engagement...

Feedback sought on genomic-led cancer control

The framework is designed to guide health professionals, researchers, health services and policy...

Can you die from long COVID? The answer is not so simple

Nearly five years into the pandemic, COVID is feeling less central to our daily lives.


  • All content Copyright © 2024 Westwick-Farrow Pty Ltd