Shopping trolleys used to detect atrial fibrillation


Friday, 30 June, 2023

Shopping trolleys used to detect atrial fibrillation

Supermarket shoppers in the UK were recently given the opportunity to be tested for a common heart rhythm disorder by holding the handlebar of a modified trolley for at least 60 seconds. The exercise was part of a study whose findings have been presented at ACNAP 2023, a scientific congress of the European Society of Cardiology (ESC).

More than 40 million people around the world have atrial fibrillation, the most common heart rhythm disorder.1 Atrial fibrillation increases the risk of stroke fivefold. These strokes are often fatal or disabling. While anticoagulation substantially lowers risk, many people only discover they have atrial fibrillation after they have a stroke.2 Screening programs are therefore needed to identify people with the condition so they can receive preventative medication.

The SHOPS-AF study investigated whether embedding electrocardiogram (ECG) sensors into the handles of supermarket trolleys could effectively identify shoppers with atrial fibrillation.3,4 Ten trolleys had a sensor placed in the handle and were used across four supermarkets with pharmacies in Liverpool during the two-month study.

If the sensor did not detect an irregular heartbeat, it lit up green. These participants had a manual pulse check by a researcher to confirm there was no atrial fibrillation. If an irregular heartbeat was found, the sensor lit up red. The in-store pharmacist then did a manual pulse check and another sensor reading using a standalone bar not attached to a trolley with the participant standing still.

The study cardiologist reviewed the ECG recordings of participants with a red light and/or irregular pulse. Participants were informed of the results, which were: 1) no atrial fibrillation; 2) unclear ECG and an invitation to repeat the measurement; or 3) atrial fibrillation confirmed and a cardiologist appointment within two weeks.

A total of 2155 adults used a shopping trolley. ECG data were available for 220 participants who either had a red light on the sensor and/or an irregular pulse, suggesting atrial fibrillation. After ECG review by the study cardiologist, there was no evidence of atrial fibrillation in 115 participants, 46 recordings were unclear, and atrial fibrillation was diagnosed in 59 participants. The average age of the 59 participants with atrial fibrillation was 74 years and 43% were women. Of those, 20 already knew they had atrial fibrillation and 39 were previously undiagnosed.

“This study shows the potential of taking health checks to the masses without disrupting daily routines,” said study author Professor Ian Jones of Liverpool John Moores University, UK. “Over the course of two months, we identified 39 patients who were unaware that they had atrial fibrillation. That’s 39 people at greater risk of stroke who received a cardiologist appointment.”

To assess the accuracy of screening using this method, the researchers conducted three analyses: 1) excluding all 46 unclear ECGs; 2) assuming all unclear ECGs were atrial fibrillation; and 3) assuming all unclear ECGs were not atrial fibrillation. This showed that the sensor’s sensitivity ranged from 0.70 to 0.93 and specificity ranged from 0.15 to 0.97. This resulted in a positive predictive value of 0.24 to 0.56, meaning that only one-quarter to one-half of those found to have atrial fibrillation according to the sensor and/or manual pulse check actually had the condition (ie, there were a high number of false positives). The negative predictive value was 0.55 to 1.00, meaning that around half of actual atrial fibrillation cases would be missed using this method (ie, false negatives).

“Nearly two-thirds of the shoppers we approached were happy to use a trolley, and the vast majority of those who declined were in a rush rather than wary of being monitored,” Jones said. “This shows that the concept is acceptable to most people and worth testing in a larger study. “Before we conduct SHOPS-AF II, some adjustments are needed to make the system more accurate. For example, having a designated position on the bar to hold onto, as hand movement interfered with the readings. In addition, ESC Guidelines require just a 30-second ECG to diagnose atrial fibrillation1, so we aim to find a sensor that will halve the time shoppers need to continuously hold the bar.

“Checking for atrial fibrillation while people do their regular shopping holds promise for preventing strokes and saving lives. A crucial aspect is providing immediate access to a health professional who can explain the findings and refer patients on for confirmatory tests and medication if needed,” he concluded.

1. Hindricks G, Potpara T, Dagres N, et al. 2020 ESC Guidelines for the diagnosis and management of atrial fibrillation developed in collaboration with the European Association of Cardio-Thoracic Surgery (EACTS). Eur Heart J. 2021;42:373–498.

2. Alshehri AM. Stroke in atrial fibrillation: Review of risk stratification and preventive therapy. J Family Community Med. 2019;26:92–97.

3. Jones ID, Lane DA, Lotto RR, et al. Supermarket/hypermarket opportunistic screening for atrial fibrillation (SHOPS-AF): a mixed methods feasibility study protocol. J Pers Med. 2022;12:578.

4. The study used a MyDiagnostick single lead ECG sensor.

Image credit: iStock.com/SomeMeans

Related News

Patient-specific 3D models to assist in surgery

UNSW engineers have their sights on developing anatomically accurate 3D printed models which...

Alfred Health deploys GE system to optimise operations

The system is designed to enhance situational awareness, communication, and overall operational...

DHCRC project to deliver benchmarking tool for AI in health

The initiative complements efforts by governments, peak organisations, and clinical professional...


  • All content Copyright © 2024 Westwick-Farrow Pty Ltd